• CYWL-100AP IoT Circuit Breaker
  • CYWL-100AP IoT Circuit Breaker
  • CYWL-100AP IoT Circuit Breaker
  • CYWL-100AP IoT Circuit Breaker
  • CYWL-100AP IoT Circuit Breaker
  • CYWL-100AP IoT Circuit Breaker
CYWL-100AP IoT Circuit Breaker
CYWL-100AP IoT circuit breaker is a multifunctional IoT smart switch that integrates power meterin……

CYWL-100AP IoT circuit breaker is a multifunctional IoT smart switch that integrates power metering, overload, short circuit, over-voltage, under-voltage, leakage, over-temperature protection, remote separation and connection, and network communication functions; and various data can be freely set, with a high-definition LCD display to display the current product status. It can be widely used in smart power management places such as commerce, agricultural water conservancy, fire data collection, schools, hospitals, rental apartments, etc.; it can also be widely used in industry, especially factory equipment energy consumption management. CYWL-100AP IoT circuit breaker can monitor and detect user load power consumption in real time. In abnormal situations, it can quickly and automatically cut off the power supply or remotely alarm to protect personal and property safety.

It can execute the disconnection charging mode, and can transmit data and execute related instructions in encrypted form through GPRS, RJ45, WIFI, RS485.

The operation status and data of the network version switch can be permanently saved, and the previous usage can be checked at any time.

The overcurrent, voltage, and leakage current protection values ​​can be set arbitrarily, which can better protect the load-end equipment circuit and realize multiple uses of one machine without having to replace the equipment.

You can set the self-test time of the product at will to ensure that the product is always in normal working condition.

You can freely set the working time period of the product.

2. Main functions and features

1. OLED dot matrix liquid crystal display, long life, good low temperature characteristics

2. It can be set as a communication gateway, and the branch small current switch can be combined and networked through the 485 interface of the main body;

3. It integrates multiple protection functions such as overvoltage, undervoltage, phase loss, phase error, loss of voltage, overload, short circuit, leakage, temperature, voltage/current imbalance, overpower and underpower, anti-theft, etc., and supports early warning according to the preset ratio

4. Multiple functions can be closed, alarmed, and skipped in any combination, with a wider range of applications

5. RS485 supports DL/T-645/ in non-gateway mode Modbus protocol and automatic conversion;

6. Support external dry node control to achieve cabinet door control;

7. Support multiple groups of arbitrary time timers to control closing and opening operations, making control more arbitrary;

8. Multi-component modular design, optional matching, more flexible use;

9. Remote wireless communication technology, supporting multiple communication modes such as №B, 2G, 4G, etc.;

10. Operation event alarm event fault event real-time reporting, allowing you to understand the operating status of your equipment anytime and anywhere; the alarm can be prompted by a buzzer, and can be muted remotely or locally, making the device alarm more intelligent

11. Support multiple remote OTA upgrade modes , so that equipment upgrade and maintenance are no longer troublesome;

12. Hundreds of event records (power on, power off) are stored locally and can be viewed at any time for accident cause analysis;

13. The clock is synchronized with the cloud on a daily basis to ensure the accuracy of event recording time. The daily error is no more than 1S without network

14. Real-time statistics of the number of events can focus on frequent abnormalities, and support Chinese and English switching display;

15. Support 12-month frozen power and 7-day daily frozen power query, making remote energy consumption management more convenient;

16. Support active, reactive, apparent power, power factor and other electrical parameters collection and upload;

17. Support positive and negative power statistics.

3. Main technical parameters and basic functions

Product classification: 1. Stand-alone version (Rs485) 2. Network version (4G+RS485) 3. Customized by customer needs (NB-Lot2GRJ45, etc.)

Number of product poles: 1P+N3P+N

Rated voltage: single-phase AC230V three-phase Ac400V50Hz

Mechanical life: more than 20,000 times

Electrical life: more than 10,000 times

Closing and opening time: closing time is less than 18S;

Opening time is less than 1S

Instantaneous trip type: C type (other types, customizable)

Rated current: 40A, 63A, 100A

Compliance with standards: GB/T10963.1GB/T16917.1

Short-circuit breaking capacity: ≥6KA

Short-circuit protection: when the line is short-circuited, the circuit breaker 0.01s Power-off protection

Leakage protection: When the line leaks, the circuit breaker will be powered off for 0.1s

Leakage protection value: 30~500mA can be set

Overvoltage and undervoltage protection: When the line is overvoltage or undervoltage, the circuit breaker will be powered off after 3S (0~99s) can be set

Overvoltage setting value: 250~320V, undervoltage setting value: 100~200V

Power-on delay: When the call comes, it will automatically close, 0-99s can be set

Power-off delay: When the power grid suddenly loses power, the circuit breaker is disconnected and in the open state, 0~10s can be set

Set rated current: 0.6~1ln

Overload delay protection: 0~99s can be set

Overtemperature protection: 0~120℃ can be set, the circuit breaker disconnection time can be set to 0~99s

Underpower: The load change amount can be set, and the circuit breaker disconnection time can be set to 0~99s

Overpower: The load change amount can be set, and the circuit breaker disconnection time can be set from 0 to 99 seconds.

Power limit: When the power limit is reached, the circuit breaker will be powered off after 3S (0-99s can be set)

Timing control: can be set, the main body can set 5 groups of time imbalance: voltage and current can be set as percentages, and the protection time can be set from 0 to 99s.

Record: 680 switch events can be queried locally

Log display: Chinese and English menus

Number: record the number of various circuit breaker operations to determine whether the circuit breaker is within the effective life

Maintenance: can set self-test, equipment reset, power reset, record reset, synchronize clock, restart equipment, restore system defaults, etc. View: local voltage, current, leakage current, temperature, active power, reactive power, apparent power, power factor, cumulative power, daily power consumption (view 7 days of records)

Manual and automatic integrated control: mobile phone APP or PC control, can be controlled by button, can also be controlled by push rod (handle control on and off; cover plate, pull rod: with anti-theft and maintenance anti-misclosing mechanical interlocking function

Communication method: RS485 standard, 2G/4G, WIFI, NB, RJ45, etc. can be selected

Software remote upgrade: according to actual use, the program can be customized to achieve remote update and upgrade

The following functions can be set to open, close, alarm or trip function

Overvoltage protection, undervoltage protection, leakage protection, overload protection, automatic closing, power failure protection, underpower protection, early warning function, timed self-test, alarm permission, gear return, high temperature protection, mutation protection, remote control, cover opening protection, underload protection, overpower protection, timing control, phase loss protection, phase mismatch protection, voltage imbalance, current imbalance




Tags:

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:89148